Product features:
★ IntelligentUV-Radiometer, automatically identifying test wavelengths
★ Color screen displays UV energy, UV light intensity, and test temperature
★ USB interface data transmission, connected to computer software to read recorded data, perform data analysis, and export test reports
★ High precision temperature sensor, fast and real-time response to test temperature
★ Large capacity data storage, capable of cycling 5 sets of 3-minute data sets, with massive data storage capacity
★ The stored data will not be lost after power failure, and the system will automatically ask whether to delete the previous data upon startup
Main parameters:
Spectral range: UVA (320-395nm)
Range: 0.1-20000mw/cm2 0.1-999999mj/cm2
Temperature limit: -55~125 ℃
Screen type: Color LCD screen
Resolution: 0.1mw/cm2 0.1mj/cm2 (high-power version)
Error range: ± 5%
Storage interval: Power storage interval 0.1S/time Temperature storage interval 0.1S/time
Temperature error: ± 1 ℃
Data storage: 5 sets of data, with a total duration of 15 minutes
Measurement mode: automatic measurement mode, manual measurement mode
Data transmission: Yes
Analysis software: Yes
Print report: Yes
Sampling speed: 0.01 seconds/time
Unit switching: MW/cm2 W/cm2
Power type: Two No. 7 alkaline batteries
Instrument size: circular diameter 120mm * height 13mm
Instrument weight: net weight 180g
Packaging weight: 1200g
Outer box size: 240mm * 205mm * 80mm
Precautions:
1. Use two No. 7 alkaline batteries. After opening the battery cover, install the battery according to the positive and negative pole markings (see inside the battery box). When the battery level on the instrument display screen is low, it should be replaced in a timely manner.
2. Optical precision instruments should avoid severe collisions and be used in a dry and clean environment as much as possible; Please store the detection window facing downwards to avoid contamination on the glass sheet of the measurement sensing window; Be sure to turn off the power after measuring.
3. Please remove the battery if not in use for a long time to avoid damaging the machine with battery filtrate.
4. Do not wipe the sensing window glass with your hands, keep the sensing window clean.
5. To ensure the consistency of instrument data, instrument data calibration can only be conducted through the manufacturer's calibration software.
6. By installing software programs on a USB drive, data analysis, importing and exporting data, and printing test reports can be performed. |
|